![](/rp/kFAqShRrnkQMbH6NYLBYoJ3lq9s.png)
Nasolacrimal Stents: An Introductory Guide - University of Iowa
2018年1月29日 · Jones Tube. Does not involve the canaliculi. The Jones tube is a Pyrex glass tube that is used to bypass an obstruction of the canalicular system in order to drain tears from the eye. It is placed from the conjunctival cul-de-sac through a surgically created bony ostium, and exits into the nose (Figure 2e).[6]
Probing and Stenting - University of Iowa
2015年4月27日 · The hook is moved medially to feel the Crawford stent. The hook is then rotated to engage the stent and the stent is removed. Once again, rotation medial to engage the stent. Sometimes a little wiggling is useful in removal of the stent. The stent is then removed. The stent is then tied with three single throws.
Crawford Stent Rescue - University of Iowa
2017年2月10日 · Crawford Stent Rescue. Richard C. Allen, MD, PhD, FACS Additional Notes: Length 02:40 Posted Feb 10, 2017 This is Richard Allen at the University of Iowa. This video demonstrates rescue of a bicanalicular stent. The patient has had an attempt at placing the Crawford stent through the upper canaliculus.
Removal of a Bicanalicular Crawford Stent - University of Iowa
2020年9月22日 · University of Iowa Carver College of Medicine. Department of Ophthalmology & Visual Sciences. 200 Hawkins Dr. Iowa City, IA 52242
Options for retrieving Crawford stents - webeye.ophth.uiowa.edu
2015年9月1日 · This video demonstrates retrieval of a Crawford stent with a hook as well as a groove director. The patient has a history of a congenital nasolacrimal duct obstruction. The Crawford stent is placed through the upper punctum and canaliculus. The stent is then rotated and advanced down the nasolacrimal duct.
Repair of lower lid canalicular laceration 1 - University of Iowa
2015年4月27日 · A Crawford stent is the placed through the punctum and retrieved from the cut end of the canaliculus. The stent is then placed through the cut end of the canaliculus and advanced to palpate a hard stop. The stent is then rotated and advanced down the nasolacrimal duct and retrieved from the nose.
Endoscopic Retrieval of Crawford Stent - University of Iowa
2015年9月1日 · The Crawford stent is visualized exiting out the distal end of the nasolacrimal duct. This area is always more inferior and lateral than you think. Again, this is visualized with the inferior turbinate, followed by the inferior meatus, followed by visualization of the Crawford stent. The stent will be retrieved with a Crawford hook.
surgeons to use Crawford stents (not described here) in primary repair. However the rounded, smooth, eyed tips of current pigtail probes make repair with the pigtail probe (as described here) an excellent option. • Jones tube (Pyrex tube placed through a dacryocystorhinostomy ostium) should be used only if other options fail, which is more ...
Jones tube placement #2 - University of Iowa
2015年10月23日 · Gentle but firm pressure with a digit is used to advance the tube. Do not use instruments for this maneuver as the instruments can break the tube. The probe is withdrawn. Examination of the tube intranasally showed it to be in good position. A double armed 6-0 Vicryl suture is then placed around the neck of the Jones tube and tied.
Atlas Entry - Jones Tube - University of Iowa
Jones tube (pyrex tube) may be used to reconstruct a functional lacrimal system. In this patient, tumor removal resulted in irreparable damage to the lacrimal system. In cases where pigtail probe repair or Crawford stenting cannot be performed, pyrex tubing such as this Jones tube may be used to reconstruct functional lacrimal drainage.